Abstract

Seismic prevention issues are discussed much more seriously around the world after Fukushima earthquake, Japan, April 2011, especially for those countries which are near the earthquake zone. Approximately kilograms of explosive energy will be released from a magnitude 9 earthquake. It destroys most of the unprotected infrastructure within several tens of miles in diameter from the epicenter. People can feel the earthquake even if living hundreds of miles away. This study is a seismic simulation analysis for an innovated and improved design of viscoelastic damping isolator, which can be more effectively applied to earthquake prevention and damage reduction of high-rise buildings, roads, bridges, power generation facilities, and so forth, from earthquake disaster. Solidworks graphic software is used to draw the 3D geometric model of the viscoelastic isolator. The dynamic behavior of the viscoelastic isolator through shock impact of specific earthquake loading, recorded by a seismometer, is obtained via ANSYS finite element package. The amplitude of the isolator is quickly reduced by the viscoelastic material in the device and is shown in a time response diagram. The result of this analysis can be a crucial reference when improving the design of a seismic isolator.

1. Introduction

Seismic isolator is a very important device to reduce the shock vibration transmitted to the buildings, equipment, transportation facilities, and so forth during earthquake. Different types of isolator such as rubber, spring, slide, rotary, and low viscosity liquid flow style are used in different environments. An important technology of reducing the vibration from sudden excitation is viscoelastic damping isolator (VDI) which can be widely used in manufacturing, electricity and gas supply, construction, transportation, and other industries. The use of viscoelastic dampers (VEDs) in high performance earthquake resistant structural systems could be effective in reducing seismic-induced responses [1].

Ou et al. analyzed the seismic responses of a single-storey structure and a multistorey structure with the viscous and viscoelastic dampers to verify the effectiveness of the passive energy dissipation devices for suppression of dynamic responses of structures and the reliability of the proposed simplified computational methods [2]. Xu used the equivalent standard solid model of viscoelastic (VE) dampers to describe the energy absorption features of VE dampers. Elastoplastic time field analysis, frequency field analysis, and shaking table tests were used to analyze responses of a 1/5 scale three-storey reinforced concrete frame structure [3]. The damping in cocured composite laminates with embedded viscoelastic layer was determined based on mode superposition and modal strain energy method [4]. Kandemir et al. investigated seismic retrofit of an existing steel arch bridge using viscous damper. Dynamic characteristics along both longitudinal and transverse directions of the bridge were analyzed by eigenvalue analysis to figure out the natural behavior under the dead load [5]. Ohsaki et al. investigated a reverse rocking response for a steel frame using a simple flexible base model consisting of truss elements. Seismic responses of the frame could be further reduced by installing viscous dampers at the support [6]. Tuned mass dampers are widely used to reduce the impact of dynamic excitations on structures. Steinbuch proposed an optimization of earthquake resistance of high buildings by multituned mass dampers via bionic algorithms [7]. Greco and Marano deal with parameter identification for basic and generalized Kelvin-Voigt and Maxwell models for fluid viscous dampers [8]. They also conducted a numerical investigation on a simple one degree of freedom structure, equipped with fluid viscous dampers.

Other researchers study seismic response via different isolators and methods. Hejazi et al. developed a three-dimensional elastoplastic viscous damper element, consisting of elastic damper in the middle part and two plastic hinges at both ends of the elements which were compatible with the constitutive model to reinforce concrete structures and were capable of detecting failure and damage to the inviscous damper device during earthquake excitation [9]. Hatzigeorgiou and Pnevmatikos proposed a simple and effective evaluating method for these maximum values using the inelastic velocity ratio [10]. This ratio was a modification factor which allowed the evaluation of the maximum inelastic velocity or damping force from their corresponding elastic counterparts. Qin et al. accomplished seismic responses of the nuclear power plants (NPPs) isolated by a friction damper isolation system (FDIS) by means of the finite element approach and setting up a representative multiparticle model of NPPs [11]. Pan et al. proposed a unified approach for long-term behavior and seismic response analysis of alkali-aggregate reaction (AAR) affected concrete dams by combining AAR kinetics, effects of creep, and plastic-damage model in the finite element method [12]. Luco obtained simple analytical expressions for the deformation of the base isolation system and of the superstructure at resonance that were in terms of an effective replacement oscillator characterized by amplitude dependent frequency, damping ratio, and excitation [13]. Numerical results suggest that the seismic response of a structure resting on an inelastic base isolation system might be larger when the flexibility of the soil was considered. Contento and Di Egidio considered the use of base isolation applied to rigid bodies placed on a multistorey frame with the aim of understanding whether or not seismic isolation was beneficial in preventing their collapse during an earthquake [14]. Turk presented the analytical study on the dynamic response of a natural stone block masonry minaret of a historical mosque [15].

Finite element method (FEM) is a common technique to analyze mechanical structure [16]. Huang et al. investigated dynamic characteristics of the viscoelastic damping isolator under impact loading through FEM and experimental analysis [17]. Impact-loading-induced vibration transmitted to the supporting medium could become the governing factor of the foundation of the production machinery [18]. Alva and Gangadharan applied ANSYS harmonic analysis to model a tuned mass absorber which was used to suppress the vibrations from harmonic excitation [19].

This research studies the normal mode vibration and seismic response of the VDI system by employing FEM to simulate the energy dissipation of the device.

2. Finite Element Analysis

The VDI is designed to support machinery equipment over 3 tons. It composes 3 plates, 8 partitions, 14 springs, and viscoelastic lipid filled between plates and partitions. The optimal number of plates and springs depends on the weight of the facility. The 3D diagram of the VDI is drawn in Solidworks and then is imported into ANSYS software. The dimension and probe location of the measured response acceleration are shown in Figure 1. The plates (partitions), springs, and viscoelastic lipid are assumed to be low carbon steel, spring steel, and polydimethylsiloxane (PDMS), respectively. Corresponding Young’s modulus, Poisson’s ratio, and density of the above three parameters are shown in Table 1. PDMS is a very soft material to represent the viscoelastic lipid. According to the research of Mathers et al., the damping ratio for PDMS material is 12.3% [20]. Hence, the modal damping ratio is assumed to be 10% in the VDI model. ANSYS Solid187 (a higher-order, 3D, 10-node element) is chosen for both of the plates and spring steel. Solid186 is a higher-order, 3D, 20-node solid element which supports plasticity, hyperelasticity, creep, stress stiffening, large deflection, and large strain capabilities. Hence, Solid186 can represent nonlinear viscoelastic behavior of PDMS. These two kinds of elements are suitable for irregular grid also. Figure 2 shows the boundary conditions and mesh of the 3D VDI. The gravity force is applied to whole body of VDI and its bottom plate is supported by the ground with frictionless contact condition between the bottom plate and the ground.

The convergence of the VDI system is examined before normal mode and impact analysis. From convergence plot as shown in Figure 3, the fundamental frequency of the VDI is converged after 65,000 elements. Hence, 70,000 elements are used for the following normal mode and seismic response analysis.

2.1. Normal Mode Analysis

ANSYS modal module is employed to execute the normal mode analysis. The boundary conditions of the VDI are fixed only at the bottom plate but free elsewhere. The modes are normal in the sense that they are independent of each other; that is, an excitation of one mode will never cause motion of a different mode. In mathematical terms, normal modes are orthogonal to each other. The most general motion of the VDI system is a superposition of its normal modes.

2.2. Seismic Response Analysis

Yang et al. employed acceleration time history recorded at Wolong station in the Wenchuan earthquake to excite the model wall [21]. Similar to Yang’s work, time history of the earthquake impact acceleration function is introduced at the bottom plate of VDI to examine the seismic response of the system in this paper. Three directions, north-south (NS, -axis), east-west (EW, -axis), and up-down (UD, -axis) of seismic motion data of Tohoku, Japan, occurring at 14:46:00, Mar. 11, 2011, magnitude 9.0, are obtained from the Center for Engineering Strong Motion Data supported by U.S. Geological Survey (USGS). Time history of Tohoku, Japan, earthquake archived 30,000 records in 300 seconds, as shown in Figure 4. The calculation and memory resources will be exhausted if one imports the whole 300-second data into the desktop PC. Therefore, only 30 seconds of data near the second pick of the earthquake, around 80 to 100 seconds, are chosen to be the seismic excitation input for the VDI system. In this case, the gravity force is applied to whole body of VDI. The bottom plate of VDI system is supported frictionless by the ground and is applied by the Tohoku earthquake acceleration function for the transient seismic analysis. However, there is no huge equipment mass applied to the top of VDI. It is only for pure investigation of the response of damper under earthquake attack.

3. Results and Discussion

The results obtained from the seismic analysis are discussed in two parts: normal mode analysis and seismic response analysis.

3.1. Normal Mode Analysis

Six fundamental natural frequencies of the VDI are shown in Table 2. The first mode is a rolling mode of the top plate on -axis at 129.5 Hz, as shown in Figure 5. The second mode is a rolling mode of the top plate on -axis at 134.3 Hz. The third mode is an up-down mode of the top plate on -axis at 181.3 Hz. The fourth mode is a yawing mode of the top plate in plane at 190 Hz, as shown in Figure 6. The fifth and sixth natural frequencies are 195.2 Hz and 195.8 Hz, respectively. The linear combination of sufficient number of normal modes can build up a general motion of VDI system.

3.2. Seismic Response Analysis

Only 30 seconds out of 300 seconds including peak magnitude of time history of the earthquake is imported carefully into ANSYS transient module as the impact function at the bottom plate of VDI to simulate the seismic response of the system. The comparison between the original earthquake time history and seismic responses obtained at the probe location of the corner of top plate in , , and directions is shown in Figures 7, 8, and 9, respectively. The peak acceleration values of the earthquake in NS (-axis), EW (-axis), and UD (-axis) are 2,670, 901, and 1,880 gal (cm/sec2), respectively. However, the peak seismic responses at the probe location of the top plate of VDI in NS (-axis), EW (-axis), and UD (-axis) are attenuated to large amounts of 16.5, 7.5, and 20 gal, respectively. Since there is no huge equipment mass placed on top of VDI and the strong stiffness of the spring, the seismic acceleration impact does not cause large deformation of the top plate of VDI. The results show that the peak value of the seismic responses is over 100 times smaller than the original value of the Tohoku earthquake. The order of the attenuation is in NS (-axis), EW (-axis), and UD (-axis) directions sequentially.

4. Conclusion

This research studies the normal mode vibration and seismic response of the VDI system by using FEM. The obtained results are summarized as follows.(1)Normal mode vibration of the VDI is obtained. The linear combination of sufficient number of normal modes can build up a general motion of VDI system. It is useful for the future design in altering the natural frequencies of VDI.(2)The VDI system can dissipate the seismic energy in huge amount smaller than the original peak acceleration of the Tohoku earthquake in all , , and directions when there is no equipment mass located on top of VDI.(3)The results show that the energy of the earthquake is quickly absorbed by the viscoelastic material to attenuate the amplitude of the top plate of the isolator. The order of the attenuation is in NS (-axis), EW (-axis), and UD (-axis) directions sequentially.

Conflict of Interests

The authors declare that there is no conflict of interests regarding the publication of this paper.