Research Article

Influence of Tensile Speeds on the Failure Loads of the DP590 Spot Weld under Various Combined Loading Conditions

Table 3

Dynamic failure loads of a spot weld for DP590 at various loading angles.

Failure Load of a spot weld for DP590 1.0 (kN)
Loading
angle
(°)
Quasi-staticDynamic
1 × 10−5 m/s0.01 m/s0.1 m/s1.2 m/s
1st2nd3rd1st2nd3rd1st2nd3rd1st2nd3rd

9.209.089.299.729.809.6310.029.9410.0810.3610.2910.21
15°8.478.388.618.818.088.949.239.169.359.439.589.69
30°8.108.228.348.898.778.738.859.068.989.299.239.36
45°8.578.558.739.139.189.269.399.489.439.689.799.56
60°10.099.8810.1310.4810.7610.6310.7410.8610.9211.1211.3811.23
75°12.6612.4212.4713.1613.0813.2313.5913.4713.7614.1813.9214.03
90°16.8817.1516.9217.9118.0217.6818.2818.6218.4519.0118.7418.89