Research Article

Stress Monitoring for Anchor Rods System in Subway Tunnel Using FBG Technology

Table 1

Test results of Group M-A (unit: kN).

Stage 1Stage 2Stage 3Stage 4Stage 5Stage 6Stage 7

1-1−0.31−3.27−3.24−2.07−2.50−3.52−21.56
1-2−0.59−4.35−4.32−2.79−3.32−6.48−33.55
2-1−0.40−2.80−2.80−2.50−2.68−4.77−33.21
2-2−0.56−3.03−3.06−2.84−2.97−7.40−40.91
3-1−0.050.680.650.470.62−3.77−12.38
3-2−0.060.320.250.120.25−1.62−8.21
4-1−0.060.620.590.712.313.0513.27
4-2−0.080.570.560.432.214.6517.30
5-10.403.913.895.564.365.969.27
5-20.403.673.674.734.114.5713.07
6-10.372.182.273.352.307.8325.91
6-20.312.062.032.592.255.6730.81
7-1−0.190.500.481.460.553.572.34
7-2−0.470.870.901.811.057.7816.45
8-1−1.01−2.05−2.07−1.44−2.15−11.75−43.59
8-2−1.16−2.19−2.17−1.64−2.23−11.80−42.12
9-1−0.77−3.24−3.27−2.98−3.20−5.67−22.42
9-2−0.97−3.53−3.56−3.24−3.46−8.27−36.81