Heat transfer-radiation test results of multilayered fabric assemblies.

Assembly numberIndexTest 1Test 2Test 3 valueLevel
RHTI24

Assembly 1Before washingRHTI24
20.8 
6.1
20.5 
6.0
20.5 
5.9
0.064 0.373
After washingRHTI24
20.4 
6.0
20.4 
5.9
20.3 
5.9


Assembly 2Before washingRHTI24
22.5 
6.7
22.4 
6.5
22.4 
6.6
0.014 0.374
After washingRHTI24
22.2 
6.6
21.9 
6.5
21.9 
6.5


Assembly 3Before washingRHTI24
22.3 
7.6
22.6 
7.9
22.6 
7.7
0.274 0.205
After washingRHTI24
22.4 
7.6
22.3 
7.6
22.4 
7.6


Assembly 4Before washingHTI24
20.4 
6.4
20.3 
6.4
20.2 
6.5
0.016 0.020
After washingHTI24
20.1 
6.3
20 
6.2
20 
6.3


Assembly 5Before washingHTI24
24.6 
7.6
24.5 
7.8
24.7 
7.8
0.001 0.007
After washingHTI24
23.9 
7.3
24.0 
7.4
23.9 
7.4