Heat transfer-flame test results of multilayered fabric assemblies.  

Assembly numberIndexTest 1Test 2Test 3 valueLevel
HTI24

Assembly 1Before washingHTI24
17.7 
4.7
17.9 
4.8
18.1 
4.9
0.006 0.025
After washingHTI24
17.2 
4.6
17.3 
4.6
17.3 
4.6


Assembly 2Before washingHTI24
18.7 
5.0
18.7 
4.9
18.8 
5.0
0.005 0.101
After washingHTI24
18.4 
4.9
18.3 
4.8
18.5 
4.9


Assembly 3Before washingHTI24
16.5 
4.1
16.1 
3.9
16.3 
4.0
0.008 0.140
X1
After washingHTI24
15.0 
3.6
14.8 
3.6
15.1 
4.0

X1

Assembly 4Before washingHTI24
14.1 
3.9
14.3 
4.1
13.7 
3.6
0.130 0.274
X1
After washingHTI24
13.8 
3.7
13.7 
3.8
13.3 
3.3

X1

Assembly 5Before washingHTI24
15.1 
4.1
15.2 
4.1
14.9 
3.9
0.155 0.105
X1
After washingHTI24
14.8 
3.9
14.9 
3.9
14.1 
3.68

X1