Research Article
Locally Corroded Stiffener Effect on Shear Buckling Behaviors of Web Panel in the Plate Girder
Table 10
Shear buckling values for the V-L-RL400R800 stiffener series.
|
Corrosion of longitudinal stiffener |
Corrosion of vertical stiffener |
Critical shear buckling load ( | Shear buckling strength ( | With corrosion/without corrosion | End (mm) | Inner (mm) | Height (mm) | Ratio | Load (kN) | Ratio | Load (kN) | Ratio | ratio | ratio |
| 400 (0.4) |
800 (0.8) | 0 | 0 | 488.35 | 1.00 | 765 | 1.00 | 0.90 | 0.94 | 100 | 0.1 | 482.4 | 0.99 | 762.5 | 1.00 | 0.89 | 0.94 | 200 | 0.2 | 473.7 | 0.97 | 762.5 | 1.00 | 0.87 | 0.94 | 300 | 0.3 | 459.95 | 0.94 | 762.5 | 1.00 | 0.84 | 0.94 | 400 | 0.4 | 444.6 | 0.91 | 737.5 | 0.96 | 0.82 | 0.91 | 500 | 0.5 | 428.6 | 0.88 | 707.5 | 0.92 | 0.79 | 0.87 |
|
|