Research Article
Locally Corroded Stiffener Effect on Shear Buckling Behaviors of Web Panel in the Plate Girder
Table 11
Shear buckling values for the V-L-RL600R400 stiffener series.
|
Corrosion of longitudinal stiffener |
Corrosion of vertical stiffener |
Critical shear buckling load ( | Shear buckling strength ( | With corrosion/without corrosion | End (mm) | Inner (mm) | Height (mm) | Ratio | Load (kN) | Ratio | Load (kN) | Ratio | ratio | ratio |
| 600 (0.6) |
400 (0.4) | 0 | 0 | 475.45 | 1.00 | 770 | 1.00 | 0.87 | 0.95 | 100 | 0.1 | 468 | 0.98 | 770 | 1.00 | 0.86 | 0.95 | 200 | 0.2 | 457.35 | 0.96 | 770 | 1.00 | 0.84 | 0.95 | 300 | 0.3 | 444.55 | 0.94 | 740 | 0.96 | 0.82 | 0.91 | 400 | 0.4 | 432.8 | 0.91 | 702.5 | 0.91 | 0.79 | 0.87 | 500 | 0.5 | 423.1 | 0.89 | 682.5 | 0.89 | 0.78 | 0.84 |
|
|