Research Article
Locally Corroded Stiffener Effect on Shear Buckling Behaviors of Web Panel in the Plate Girder
Table 12
Shear buckling values for the V-L-RL600R800 stiffener series.
|
Corrosion of longitudinal stiffener |
Corrosion of vertical stiffener |
Critical shear buckling load ( | Shear buckling strength ( | With corrosion/without corrosion | End (mm) | Inner (mm) | Height (mm) | Ratio | Load (kN) | Ratio | Load (kN) | Ratio | ratio | ratio |
| 600 (0.6) |
800 (0.8) | 0 | 0 | 476.3 | 1.00 | 755 | 1.00 | 0.87 | 0.93 | 100 | 0.1 | 469.3 | 0.99 | 755 | 1.00 | 0.86 | 0.93 | 200 | 0.2 | 458.45 | 0.96 | 755 | 1.00 | 0.84 | 0.93 | 300 | 0.3 | 442.25 | 0.93 | 742.5 | 0.98 | 0.81 | 0.92 | 400 | 0.4 | 426.55 | 0.90 | 702.5 | 0.93 | 0.78 | 0.87 | 500 | 0.5 | 414.35 | 0.87 | 680 | 0.90 | 0.76 | 0.84 |
|
|