Table of Contents Author Guidelines Submit a Manuscript
Advances in Materials Science and Engineering
Volume 2015, Article ID 642061, 12 pages
http://dx.doi.org/10.1155/2015/642061
Research Article

The Performance of Calcium Silicate Board Partition Fireproof Drywall Assembly with Junction Box under Fire

Department of Architecture, National Taiwan University of Science and Technology, No. 43, Section 4, Keelung Road, Taipei 10607, Taiwan

Received 22 April 2015; Accepted 14 July 2015

Academic Editor: Ana S. Guimarães

Copyright © 2015 Yinuo Wang et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Linked References

  1. Y.-J. Chuang, W.-T. Wu, H.-Y. Chen, C.-H. Tang, and C.-Y. Lin, “Experimental investigation of fire wall insulation during a standard furnace fire test with different initial ambient air temperatures,” Journal of Applied Fire Science, vol. 15, no. 1, pp. 41–55, 2006. View at Publisher · View at Google Scholar · View at Scopus
  2. M.-C. Ho and M.-J. Tsai, “Relative importance of fire resistance performance of partition walls,” Journal of Marine Science and Technology, vol. 18, no. 3, pp. 430–434, 2010. View at Google Scholar · View at Scopus
  3. C. T. Do, D. P. Bentz, and P. E. Stutzman, “Microstructure and thermal conductivity of hydrated calcium silicate board materials,” Journal of Building Physics, vol. 31, no. 1, pp. 55–67, 2007. View at Publisher · View at Google Scholar · View at Scopus
  4. S.-H. Lin, C.-L. Pan, and W.-T. Hsu, “Monotonic and cyclic loading tests for cold-formed steel wall frames sheathed with calcium silicate board,” Thin-Walled Structures, vol. 74, pp. 49–58, 2014. View at Publisher · View at Google Scholar · View at Scopus
  5. I. Maruyama, G. Igarashi, Y. Nishioka, and Y. Tanigawa, “Carbonation and fastening strength deterioration of calcium silicate board: analysis of materials collected from a ceiling collapse accident,” Journal of Structural and Construction Engineering, vol. 78, no. 689, pp. 1203–1208, 2013. View at Publisher · View at Google Scholar · View at Scopus
  6. M. Nithyadharan and V. Kalyanaraman, “Experimental study of screw connections in CFS-calcium silicate board wall panels,” Thin-Walled Structures, vol. 49, no. 6, pp. 724–731, 2011. View at Publisher · View at Google Scholar · View at Scopus
  7. P. C. R. Collier and A. H. Buchanan, “Fire resistance of lightweight timber framed walls,” Fire Technology, vol. 38, no. 2, pp. 125–145, 2002. View at Publisher · View at Google Scholar · View at Scopus
  8. A. Y. Nassif, I. Yoshitake, and A. Allam, “Full-scale fire testing and numerical modelling of the transient thermo-mechanical behaviour of steel-stud gypsum board partition walls,” Construction and Building Materials, vol. 59, pp. 51–61, 2014. View at Publisher · View at Google Scholar · View at Scopus
  9. International Organization for Standardization, ISO 834-1, Fire-Resistance Tests-Elements of Building Construction: Part1: General Requirements, International Organization for Standardization, London, UK, 1999.
  10. M. A. Sultan, “Incident heat flux measurements in floor and wall furnaces of different sizes,” Fire and Materials, vol. 30, no. 6, pp. 383–396, 2006. View at Publisher · View at Google Scholar · View at Scopus
  11. CNS 5534, “Thermocuples,” 1982.
  12. T.-H. Tsai, S.-Y. Kuo, Y.-T. Tseng, C.-H. Tang, Y.-J. Chuang, and C.-Y. Lin, “Rates of smoke leakage through firestops,” Journal of Engineering Research, vol. 1, no. 1, pp. 231–250, 2013. View at Google Scholar · View at Scopus
  13. NFPA 70, National Fire Protection Association, National Electrical Code, 2008.