Research Article
Mechanical Performance versus Corrosion Damage Indicators for Corroded Steel Reinforcing Bars
Table 2
Experimental results of LCF tests for different testing frequency and percentage differences.
| Frequency | 2.0 Hz | 0.05 Hz | | Frequency | 2.0 Hz | 0.05 Hz | | Cycle | [MPa] | [MPa] | Difference [%] | Cycle | | | Difference [%] |
| 1 | 31.7 | 33 | 3.90% | 1 | 31.6 | 33.7 | 6.4% | 2 | 31.5 | 33 | 4.50% | 2 | 31.7 | 29.8 | 6.2% | 3 | 30.9 | 32.4 | 4.60% | 3 | 28.3 | 27.8 | 1.8% | 4 | 29.4 | 31.8 | 7.50% | 4 | 25.7 | 25.2 | 1.9% | 5 | 29.3 | 31.1 | 5.80% | 5 | 23.7 | 23.3 | 1.8% | 6 | 28.4 | 30.5 | 6.90% | 6 | 22.1 | 21.7 | 1.8% | 7 | 27.8 | 29.9 | 7.00% | 7 | 20.8 | 20.4 | 2.0% | 8 | 27.3 | 29.4 | 7.10% | 8 | 19.6 | 19.2 | 2.5% | 9 | 26.2 | 28.8 | 9.00% | 9 | 18.5 | 18.0 | 3.1% | 10 | 26.0 | 28.6 | 9.10% | 10 | 17.5 | 17.0 | 3.1% | 11 | 25.8 | 27.7 | 6.90% | 11 | 16.3 | 16.0 | 2.1% | 12 | 25.2 | 27.1 | 7.00% | 12 | 15.0 | 15.1 | 1.0% | 13 | 24.6 | 26.3 | 6.50% | 13 | 13.3 | 14.3 | 6.8% | 14 | 23.8 | 25.5 | 6.70% | | | | | 15 | 23.2 | 24.2 | 4.10% | | | | | 16 | 22.6 | 21.6 | 4.60% | | | | |
| Total | 433.7 | 460.9 | 5.90% (tot) | | 284.1 | 281.5 | 0.92% (tot) |
|
|