Research Article

Mechanical Performance versus Corrosion Damage Indicators for Corroded Steel Reinforcing Bars

Table 3

Mean values and coefficient of variation of residual mechanical properties of corroded bars (16 and 25 mm), tensile tests.

Steel grade/processLabMLres.res.res.
[mm][days][%][%][%][%][%][%][%][%][%]

B400C-TEMP16A909.393.61.789.71.095.82.329.911.8
B450C-TEMP16A9010.994.92.490.42.695.23.327.120.9
B500B-TEMP16A9010.893.70.489.00.993.81.921.111.6
B400C-TEMP16B9016.492.91.894.50.9101.72.544.811.6
B450C-TEMP16B9010.396.52.099.21.1102.81.039.014.0
B500B-TEMP16B9024.787.61.393.70.8106.81.247.67.6
B450C-TEMP16C903.296.31.497.71.3101.41.245.626.4
B500B-TEMP16C900.395.21.195.10.999.90.670.724.2
B400C-TEMP16C900.397.42.396.80.799.41.975.59.9
B450C-TEMP25B903.897.41.597.50.6100.10.962.68.3
B500B-TEMP25B909.099.00.497.10.598.20.372.74.4
B450C-TEMP25C901.4100.90.999.00.798.11.283.79.3
B500B-TEMP25C901.799.50.997.20.997.51.372.419.4