Ec and cement properties following laboratory grinding.

Control cement Cement with glycol-based GA at 530 g/ton Cement with amine-based GA at 460 g/ton
Test number121212

Ec, kWh/ton 43.2743.2739.638.8740.3340.33
43.27 (0%)39.23 (1.31%)40.33 (0%)

Blaine, cm2/g387038253810377538803790
3848 (0.82%)3792 (0.65%)3835 (1.66%)

R-90, %5.85.36.77.45.76.4
5.55 (6.37%)7.05 (7.02%)6.05 (8.2%)

R-45, %18.317.72323.319.622
18 (2.36%)23.15 (0.91%)20.8 (8.16%)

0.8930.8880.7820.810.7480.771
0.891 (0.39%)0.796 (2.48%)0.759 (2.14%)

, m23.525.127.826.922925.8
24.3 (4.65%)27.35 (2.32%)27.4 (8.26%)

Water demand, %27.727.827.927.527.727.3
27.75 (0.25%)27.7 (1.02%)27.5 (1.03%)

Final setting, min210215225215205190
212.5 (1.7%)220 (3.21%)197.5 (5.37%)

1-day compression, MPa14.314.716.315.91715.8
14.5 (1.95%)16.1 (1.75%)16.4 (5.17%)

28-day compression, MPa46.444.84244.254.349.2
45.6 (2.48%)43.1 (3.61%)51.7 (6.97%)

The mean of two values is considered for analysis. The COV is given between parentheses.