Research Article

Characteristics of Humidity-Temperature Changing in the Below-Grade Concrete Structure by Applying Waterproofing Materials on the Exterior Wall

Table 4

Compressive strength of the concrete specimen.

DivisionResultTest method

Compressive strength test
 HPC29.34 MPaKS F 2403
 OPC17.82 MPa
Rebound hardness test
 HPC27.44 MPaSchmidt hammer test
 OPC18.29 MPa