Research Article

Effect of Nickel Content on the Corrosion Resistance of Iron-Nickel Alloys in Concentrated Hydrochloric Acid Pickling Solutions

Table 1

Corrosion data obtained from the polarization curves for Fe-36% Ni and Fe-45% Ni in 1 M HCl solutions.

AlloyCorrosion parameter
/V/dec−1/V/Vdec−1/Acm−2/cm2/mpy

Fe-36% Ni0.135−0.4750.03555.02.19719.44
Fe-45% Ni0.100−0.2480.0482.070.500.728