Modulus test result of rubber bearing.

SequenceForce (kN)Displacement (mm)StrainModulus (MPa)

Preloading45
1900.149250.0074625134.00
21350.344250.0172125116.19
31800.553750.0276875108.35
42250.837250.041862595.55

Average113.53