Experimental Study of Dowel Bar Alternatives Based on Similarity Model Test
Table 1
Modulus test result of rubber bearing.
| Sequence | Force (kN) | Displacement (mm) | Strain | Modulus (MPa) |
| Preloading | 45 | | | | 1 | 90 | 0.14925 | 0.0074625 | 134.00 | 2 | 135 | 0.34425 | 0.0172125 | 116.19 | 3 | 180 | 0.55375 | 0.0276875 | 108.35 | 4 | 225 | 0.83725 | 0.0418625 | 95.55 |
| Average | 113.53 |
|
|