Research Article

Static Pull Testing of a New Type of Large Deformation Cable with Constant Resistance

Table 3

Calculation results of energy of CRLD cable.

Number Basic parameterResistance /JAbsorbing /JTotal /JSpecification
CR-F /kNCR-displacement /mmMax-displacement /mm

Test 58502502000106.251487.501593.75CRLD-I
Test 6800200200080.001440.001520.00CRLD-I
Test 7140200200014.00252.00266.00CLRD-III
Test 819010020009.50361.00370.50CLRD-III
Test 9220125200013.75412.50426.25CLRD-III
Test 10190125200011.88356.30368.13CLRD-III
Test 11450100200022.50855.00877.50CRLD-II
Test 12900150200067.501665.001732.50CRLD-I
Test 13500150200037.50925.00962.50CRLD-II
Test 147018020006.30127.40133.70CRLD-III
Test 15850200200085.001530.001615.00CRLD-I
Test 16600100200030.001140.001170.00CRLD-I

Note. The displacement when CRLD cable achieves constant resistance moment. (CR-displacement).
The displacement when CRLD cable achieves maximum constant resistance moment (max-displacement).