Research Article

An Electrochemical Study to Evaluate the Effect of Calcium Nitrite Inhibitor to Mitigate the Corrosion of Reinforcement in Sodium Chloride Contaminated Ca(OH)2 Solution

Table 3

Electrochemical parameters extracted after fitting of EIS plots in suitable EEC of steel rebar exposed in solutions.

[Cl/]Concentration of NaCl (g/L)Rs (Ω) (kΩ⋅cm2)CPE⁢

−1⋅cm−2s−n)
n
()
(Ω⋅cm2s0.5)
Efficiency (E%)

0.00.99180.070.860.30.87
7.9169.258.175.90.860.87
0.30.9960.9219.034.40.9367.67
7.9138.0170.045.10.9165.82
0.60.9958.3349.031.50.943.4079.71
7.9130.9268.043.50.9410.0078.32
1.20.9951.6497.030.60.943.9085.75
7.9123.1347.042.60.9411.2083.26