Research Article
Mechanical and Failure Criteria of Air-Entrained Concrete under Triaxial Compression Load after Rapid Freeze-Thaw Cycles
Table 2
Experimental results of air-entrained concrete under triaxial compression after rapid freeze-thaw cycles (MPa).
| Freeze-thaw cycles | α | | | | | | | |
| 0 | 0.1 : 0.25 : 1 | 10.45 | 24.38 | 95.81 | 43.55 | 37.39 | 1.70 | 1.46 | 0.1 : 0.5 : 1 | 11.84 | 52.92 | 105.39 | 56.72 | 38.29 | 2.21 | 1.49 | 0.1 : 0.75 : 1 | 9.96 | 69.30 | 92.35 | 57.20 | 34.71 | 2.23 | 1.35 | 0.1 : 1 : 1 | 10.04 | 85.01 | 85.22 | 60.09 | 35.39 | 2.34 | 1.38 |
| 100 | 0.1 : 0.25 : 1 | 10.45 | 24.29 | 95.40 | 43.38 | 37.22 | 1.69 | 1.45 | 0.1 : 0.5 : 1 | 10.98 | 49.92 | 99.60 | 53.5 | 36.27 | 2.09 | 1.41 | 0.1 : 0.75 : 1 | 9.95 | 66.92 | 89.20 | 55.36 | 33.37 | 2.16 | 1.30 | 0.1 : 1 : 1 | 10.13 | 84.51 | 84.75 | 59.80 | 35.12 | 2.33 | 1.37 |
| 200 | 0.1 : 0.25 : 1 | 9.49 | 21.62 | 84.95 | 38.69 | 33.09 | 1.51 | 1.29 | 0.1 : 0.5 : 1 | 9.32 | 42.45 | 84.48 | 45.42 | 30.76 | 1.77 | 1.20 | 0.1 : 0.75 : 1 | 8.82 | 59.55 | 79.46 | 49.28 | 29.74 | 1.92 | 1.16 | 0.1 : 1 : 1 | 8.77 | 73.12 | 73.33 | 51.74 | 30.38 | 2.02 | 1.19 |
| 300 | 0.1 : 0.25 : 1 | 7.15 | 16.20 | 63.46 | 28.94 | 24.69 | 1.13 | 0.96 | 0.1 : 0.5 : 1 | 8.22 | 37.14 | 73.92 | 39.76 | 26.89 | 1.553 | 1.05 | 0.1 : 0.75 : 1 | 8.58 | 57.09 | 76.09 | 47.25 | 28.42 | 1.843 | 1.11 | 0.1 : 1 : 1 | 7.87 | 66.10 | 66.33 | 46.77 | 27.50 | 1.823 | 1.07 |
| 400 | 0.1 : 0.25 : 1 | 6.66 | 15.41 | 60.51 | 27.53 | 23.59 | 1.07 | 0.92 | 0.1 : 0.5 : 1 | 7.49 | 34.22 | 68.25 | 36.65 | 24.86 | 1.43 | 0.97 | 0.1 : 0.75 : 1 | 6.92 | 45.52 | 60.70 | 37.71 | 22.64 | 1.47 | 0.88 | 0.1 : 1 : 1 | 7.57 | 59.55 | 59.97 | 42.36 | 24.60 | 1.65 | 0.96 |
|
|