Review Article

Electrical Resistivity of Concrete for Durability Evaluation: A Review

Table 5

Classification of concrete permeability to surface resistivity values.

RCP test versus surface resistivity
Chloride ion permeabilityRCP test charged passed (Coulombs) Surface Resistivity Test
cylinder
(kΩ-cm)

(measured)
cylinder
(kΩ-cm)

(measured)
Semi-infinite slab
(real)
KDOT
cylinder
(kΩ-cm)

(measured)

High>4000<12<9.5<6.7<7.0
Moderate2000–400012–219.5–16.56.7–11.77.0–13.0
Low1000–200021–3716.5–2911.7–20.613.0–24.3
Very low100–100037–25429–19920.6–141.124.3–191
Negligible<100>254>199>141.1>191