Review Article

Electrical Resistivity of Concrete for Durability Evaluation: A Review

Table 6

Concrete resistivity and risk of corrosion of steel reinforcement.

Corrosion risk Resistivity values (kΩ·cm)
Polder [7]Song and Saraswathy [66], Elkey and Sellevold [67]Commercial Wenner probe instrument manuals [68, 69]

High<10<5≤10
Moderate10–505–1010–50
Low50–10010–2050–100
Negligible>100>20≥100