Research Article
Optimal Heat Transfer Coefficient Distributions during the Controlled Cooling Process of an H-Shape Steel Beam
Table 3
The optimization search of
distribution for Case 3 (e.g., with ten points).
| Number | | | | | | | | W/m2K | W/m2K | W/m2K | W/m2K | W/m2K | °C | °C |
| (1) (constant) | 1200 | 1200 | 1200 | 1200 | 120 | 543 | 179 | (2) | 1213 | 945 | 934 | 1087 | 101 | 552 | 210 | (3) | 1168 | 1013 | 1000 | 1140 | 151 | 553 | 189 | (4) | 1121 | 1081 | 1065 | 1192 | 201 | 553 | 168 | (5) | 1074 | 1148 | 1130 | 1243 | 201 | 555 | 147 | (6) | 1038 | 1213 | 1191 | 1267 | 182 | 556 | 133 | (7) | 1017 | 1278 | 1254 | 1280 | 204 | 556 | 131 | (8) | 991 | 1353 | 1323 | 1265 | 203 | 557 | 123 | (9) | 959 | 1435 | 1398 | 1223 | 181 | 559 | 111 | (10) (optimization) | 913 | 1579 | 1556 | 1166 | 225 | 560 | 104 |
|
|