Research Article

Effect of Particle Size of Periclase on the Periclase Hydration and Expansion of Low-Heat Portland Cement Pastes

Table 4

Hydration degree of periclase in LHC cement pastes cured for 7, 28, 60, 90, 180, and 240 d (%).

Particle size of periclase (μm)Curing temperature, T (°C)The hydration degree of periclase (%)
0 d7 d28 d60 d90 d180 d240 d

2.60200.000.273.774.8516.7129.3830.73
3.92200.006.8011.0511.3315.8619.5524.36
4.00200.006.6911.6312.7916.2825.2928.20
4.00400.008.4325.8736.6339.2445.9345.93
4.00800.0032.5648.5561.9263.6666.5767.15