Sample data of back analysis with BP network.

Sample numbers, C1 (C2) (kJ/(m·d·°C)), C1 (C2) (kJ/(kg·°C)), C1 (C2) (kJ/(m3·d)), C1 (C2) (°C), C1 (C2)

10 (0)377.59 (373.27)0.876 (0.864)0 (0)26.7 (27.1)
20.041 (0.273)373.01 (346.25)0.876 (0.866)2246.67 (13576.07)27.75 (33.53)
30.058 (0.454)371.57 (328.34)0.876 (0.867)3149.57 (22562.93)28.17 (37.76)
40.053 (0.553)370.17 (319.94)0.876 (0.869)2924.09 (27552.24)28.06 (40.10)
50.058 (0.597)368.82 (313.09)0.877 (0.869)3150.02 (29785.34)28.17 (41.14)
1460.899 (0.907)290.51 (287.93)0.887 (0.874)49788.84 (45449.35)47.4 (47.82)