Research Article

Experimental Investigation of the Surface Temperature Distribution and Thermal Performance of an Intermittent Combustion Chinese Heated Wall

Table 2

Testing scenarios (Tests 1–3).

TestDateCombustion(s)Amount of wood for one combustion (kg)NumberIgnitionTime stopped adding woodTime outlet was shut

Test 12014-11-23 8:40∼22:00Two times per day7.51a9:009:4010:10
1b16:0016:4017:05

Test 22014-11-29, 8:30∼2014-12-1 7:20Two times for day 1, three times for day 27.52a9:009:4010:10
2b16:0016:4017:05
2c8:008:409:10
2d12:0012:3012:50
2e19:0019:3519:55

Test 32015-3-25 19:30∼21:35Single combustion7.53a19:4520:3021:00