Research Article

Development of Dynamic Impact Factor Expressions for Skewed Composite Concrete-Steel Slab-On-Girder Bridges

Table 1

Impact factors specified by various codes.

CountryImpact factor (IF)Code (specification)

US[15.24/(L + 38.10)] ≤ 0.30AASHTO [28]
UK0.25BS5400 [29]
France[0.64/(1 + 0.2 L)] ≤ 0.30French cahier des prescriptions
[0.80/(1 + 0.2 L)] ≤ 0.30
Germany0.4 – 0.008 L(m) − 0.1 hDIN 1072–1976
Iran0.3 – 0.005 L(m) − 0.15 h h ≥ 0Iranian specification bridge code