Table 3

GEV distribution parameters for HE-A with different numbers of sampling units ( and ) in 2009 and its correspondence error in comparison with the observed data.

Vessel HE-A20092009
(mm/y) (mm/y)(mm/y)(mm/y)p value (K–S test) (mm/y) (mm/y)(mm/y)(mm/y)p value (K–S test)
0.240.310.852.3631.1900.070.180.250.972.191.010.05
µe (%)σe (%)µe (%)σe (%)µe (%)σe (%)µe (%)σe (%)
19.197.845.838.8121.287.986.898.97