Research Article

Magnetic Fluids’ Heating Power Exposed to a High-Frequency Rotating Magnetic Field

Table 1

Maximal temperature derivative: comparison of AMF and RMF.

f (kHz)H (kA/m)AMF (dT/dt)max (K/s)RMF (dT/dt)max (K/s)RMF/AMF

1304.10.13330.27332.0503
1604.10.24010.52672.1937
2442.00.10000.20672.0670
5042.00.24670.66672.7025
6711.00.07330.12671.7285
7791.00.11330.16671.4713