Research Article

Numerical and Experimental Analysis of the Shear Behavior of Ultrahigh-Performance Concrete Construction Joints

Table 5

Measured compressive strengths for the UHPC.

CaseCompressive strength (MPa)Average compressive strength (MPa)Standard deviation (MPa)Coefficient of variation
1 (min)23 (max)

First pouring202.0204.7207.2204.62.120.010
Second pouring185.2187.0188.8187.01.470.007