Research Article

Effect of Polymer-Ceramic Fibre Interphase Design on Coupling Factor in Low Fibre Volume Content Piezoelectric Composites

Figure 4

The average (a) polarization evolution (PE) loop and (b) the strain evolution (SE) loop results from 3 fibres, each tested with no significant differences in the ferroelectric properties between fibres coated with the interlayer polymer (Beckopox EM 2120w/45WA) and the uncoated fibres.
(a)
(b)