Research Article
Stress Corrosion Behavior of Ungrouted Pretensioned Concrete Beams
Table 4
AC impedance parameters for the rebar and prestressed steel in chloride-contaminated concrete.
| System | AC impedance parameters | Rebar | Prestressed steel wire | Rct (Ω·cm2) × 104 | Cdl (F·cm−2) × 10−5 | Icorr (mA·cm2) × 10−3 | CR (mmpy) × 10−2 | Rct (Ω·cm2) × 104 | Cdl (F·cm−2) × 10−5 | Icorr (mA·cm2) × 10−3 | CR (mmpy) × 10−2 |
| Control | 4.897 | 1.733 | 0.533 | 0.617 | 4.355 | 1.623 | 0.599 | 0.694 | 1% NaCl | 4.010 | 2.225 | 0.651 | 0.754 | 3.766 | 2.088 | 0.692 | 0.803 | 2% NaCl | 2.357 | 2.417 | 1.107 | 1.283 | 2.286 | 3.174 | 1.141 | 1.323 | 3% NaCl | 2.131 | 2.618 | 1.224 | 1.419 | 1.441 | 5.125 | 1.810 | 2.098 |
|
|