Research Article
Experimental Study on Strain Penetration Effects in Fixed-End Rotation of RC Beam-Column Connections with High-Strength Reinforcement
Table 7
Additional fixed-end rotation of interior beam-column connection at yielding and nominal ultimate limit states.
| Specimen no. | sy (mm) | θy,slip (×10−3 rad) | su (mm) | θu,slip (×10−3 rad) | E | W | E | W | E | W | E | W |
| IA-400-C40-18 | 0.50 | 0.50 | 2.41 | 2.40 | 0.82 | 0.82 | 3.44 | 3.43 | IA-400-C50-18 | 0.46 | 0.48 | 2.15 | 2.25 | 0.78 | 0.83 | 3.11 | 3.29 | IA-400-C60-18 | 0.48 | 0.47 | 2.13 | 2.09 | 1.08 | 1.06 | 4.03 | 3.96 | IA-600-C40-20 | 0.58 | 0.56 | 2.74 | 2.66 | 1.23 | 1.18 | 4.81 | 4.64 | IA-600-C50-20 | 0.55 | 0.54 | 2.66 | 2.63 | 0.82 | 0.89 | 3.46 | 3.77 | IA-600-C60-20 | 0.52 | 0.51 | 2.42 | 2.39 | 1.02 | 1.09 | 3.99 | 4.25 | IA-800-C40-22 | 0.65 | 0.62 | 3.05 | 2.88 | 1.23 | 1.26 | 4.84 | 4.95 | IA-800-C50-22 | 0.58 | 0.63 | 2.73 | 2.95 | 1.17 | 1.16 | 4.53 | 4.49 | IA-800-C60-22 | 0.55 | 0.56 | 2.68 | 2.73 | 1.01 | 1.01 | 4.11 | 4.10 | IB-400-C40-18 | 0.55 | 0.56 | 2.72 | 2.76 | 0.81 | 0.82 | 3.44 | 3.48 | IB-400-C50-18 | 0.54 | 0.54 | 2.49 | 2.52 | 0.96 | 0.98 | 3.91 | 3.98 | IB-400-C60-18 | 0.53 | 0.53 | 2.36 | 2.38 | 0.94 | 0.93 | 3.55 | 3.52 | IB-600-C40-20 | 0.67 | 0.67 | 3.12 | 3.11 | 1.10 | 1.13 | 4.46 | 4.58 | IB-600-C50-20 | 0.65 | 0.63 | 2.92 | 2.83 | 1.23 | 1.19 | 4.76 | 4.63 | IB-600-C60-20 | 0.62 | 0.63 | 2.88 | 2.90 | 1.19 | 1.11 | 4.82 | 4.50 | IB-800-C40-22 | 0.75 | 0.78 | 3.55 | 3.69 | 1.18 | 1.16 | 4.83 | 4.75 | IB-800-C50-22 | 0.76 | 0.76 | 3.61 | 3.61 | 1.26 | 1.17 | 5.04 | 4.70 | IB-800-C60-22 | 0.69 | 0.71 | 3.05 | 3.13 | 1.42 | 1.42 | 5.40 | 5.39 |
|
|