Research Article

Experimental Study on Strain Penetration Effects in Fixed-End Rotation of RC Beam-Column Connections with High-Strength Reinforcement

Table 8

Additional fixed-end rotation of exterior beam-column connection at yielding and nominal ultimate states.

Specimen no.sy (mm)θy,slip (×10−3 rad)su (mm)θu,slip (×10−3 rad)

EA-430-C40-180.703.371.164.83
EA-380-C50-180.683.281.234.94
EA-420-C50-200.783.901.265.43
EA-350-C60-180.672.981.234.68
EA-330-C40-200.693.241.274.95
EA-300-C50-200.673.361.094.70
EA-270-C60-200.582.721.034.11
EA-300-C60-220.622.771.094.09
EA-190-C40-200.462.140.883.45
EA-210-C40-220.432.100.803.22
EA-190-C50-220.432.000.953.74
EA-160-C60-200.432.000.773.08
EB-420-C40-180.803.841.255.28
EB-420-C50-180.773.601.255.10
EB-420-C50-200.803.801.285.00
EB-400-C60-180.713.171.264.81
EB-380-C40-200.823.921.405.91
EB-340-C50-200.703.151.204.67
EB-310-C60-200.673.111.224.95
EB-340-C60-220.753.341.264.78
EB-220-C40-200.592.811.094.61
EB-230-C40-220.582.860.964.03
EB-210-C50-220.542.550.973.89
EB-180-C60-200.502.300.803.24