Research Article
Protection of Brass in HCl Solution by L-Cysteine and Cationic Surfactant
Table 3
Corrosion parameters for brass in acidic chloride solution after immersion in cysteine and SDS solutions for various periods of time.
| Cinh (mol/dm3) | t (min) | Ecorr (V) versus SCE | jcorr (μA/cm2) | ba (V) | bc (V) |
| 1·10−2 Cys | 15 | −0.129 | 9 | 0.079 | −0.099 | 30 | −0.140 | 8 | 0.072 | −0.155 | 60 | −0.127 | 7.5 | 0.067 | −0.262 | 1140 | −0.120 | 7 | 0.074 | −0.256 |
| 1·10−3 SDS | 15 | −0.213 | 3 | 0.048 | −0.075 | 30 | −0.201 | 2.3 | 0.05 | −0.0725 | 60 | −0.194 | 1.6 | 0.037 | −0.066 | 1200 | −0.173 | 1 | 0.028 | −0.049 | 4080 | −0.123 | 0.64 | 0.027 | −0.046 |
|
|