Research Article

Auxiliary Piers on Long-Span Specially Shaped Mixed Steel Structure Main Tower Cable-Stayed Bridge: Research on the Impact on the Dynamic Performance

Table 11

Displacements and axial forces of the three structural models under longitudinal bridge excitation.

Structure typeMaximum displacement of the tower top (mm)Maximum displacement in the middle of the span (mm)Maximum axial force in the middle of the span (kN)
Cross bridgeLongitudinal directionVerticalCross bridgeLongitudinal directionVertical

Model 1039.5161.300.0711.7654.592.37 × 104
Model 4039.7061.390.0701.806.151.80 × 104
Model 5039.2161.580.0831.700.372.94 × 104