Research Article

Mechanism and Application of Static Fracturing Technology on Deep Working Face

Table 7

Orthogonal test data.

IndicatorsSchemes
123456

Peak stress ΔU (MPa)15.4513.0510.177.1428.0126.78
Width of plastic zone ΔL (m)1.090.420.50.5420.62
Volume of plastic zone ΔV (m3)1.490.530.811.2612.491.38
789101112
Peak stress ΔU (MPa)14.0018.5447.6042.9733.3626.46
Width of plastic zone ΔL (m)0.610.6220.910.880.84
Volume of plastic zone ΔV (m3)1.940.4125.333.480.721.21