Research Article

Monitoring and Assessment of Cemented Paste Backfill Containing Coal Gangue and Fly Ash in an Underground Mine

Table 2

Parameters of sensors.

Sensor typeParametersFigures of sensors

Temperature and humidity sensorsWorking voltage: 3–5 V; temperature measurement range: 0°C–50°C; humidity measurement range: 20–100%RH; temperature measurement accuracy 1°C; humidity measurement accuracy: 1% RH; transmission system RS485; transmission maximum distance: 1.2 km

Hydration temperature sensorWorking voltage: 3–5 V; temperature measurement range: −55°C–+125°C; temperature measurement accuracy: ±0.5°C; transmission system: RS485; transmission maximum distance: 1.2 km

Stress meterWorking voltage DC 18 V; working current:≤20 mA; transmission system: RS485; the cross-sectional area of transmission cables: 0.43 mm2; transmission maximum distance: 1 km; measuring span 0–30 MPa; measuring error: ≤4.0% (FS); main dimension: φ118∗60.5 mm

Displacement meter of CCGPBParameters: setting; working voltage: DC 18 V; working current: ≤20 mA; transmission system: RS485; cross-sectional area of transmission cables: 0.43 mm2; transmission maximum distance: 1 km; measuring span: 0–500 mm; measuring error: ≤4.0% (FS); main dimension: φ186∗3000 mm