Abstract

Concrete materials are an important part of global structure, and their fire resistance directly affects the safety of buildings and tunnels. In this study, basalt fiber was used to reinforce concrete with high content of stone powder in order to enhance its high-temperature performance. The mechanical properties and ultrasonic characteristics at different temperatures were studied using the cube compressive strength test and nonlinear ultrasonic test. The results indicated that the addition of basalt fiber in specimens improved their compressive strength; however, this strength did not continuously increase with increases in the fiber length and fiber content, and the optimal values for fiber length and fiber content were determined to be 12 mm and 1 kg/m3 at 600°C, respectively. With increases in temperature, the unconfined compressive strength increased first and then decreased. When the temperature was 400°C, the unconfined compressive strength of the specimens reached their highest values and then decreased. When the temperature was 400°C and 600°C, the strength of the stone powder concrete with fiber was higher than that without fiber, which shows that fiber can improve the mechanical properties of concrete at high temperatures. Based on the Box-Behnken design (BBD) method, the unconfined compressive strength response regression model of basalt fiber-reinforced concrete with high content of stone powder, which follows parameters including fiber content, fiber length, and temperature at high-temperature environments, was established, and it was found that the interaction of fiber content, fiber length, and the temperature was significant based on multifactor interaction analysis. The analysis of ultrasonic signals based on the S transform showed that, with increases in temperature, the amplitudes of the acoustic response signals, the corresponding frequency spectrum, and the time-frequency spectrum were clearly reduced. At the same temperature, the amplitudes of the acoustic response signals of different concrete testing blocks did not change much and remained at the same level.

1. Introduction

Concrete is one of the cement products used in many parts of construction, such as buildings, bridges, tunnels, and roads. Studies show that the cement industry demands a vast amount of energy and also releases a large amount of carbon dioxide into the atmosphere—up to 13,500 tons per year, which is 7% of greenhouse gas emissions annually produced and causes additional environmental pollution [1, 2]. Therefore, many scholars are currently devoted to the study of cement alternative materials.

It has been found that some fillers, such as limestone fines, granite dust, quartzite fines, rock dust, and recycled crushed stone powder, are good substitutes for cement and other cementitious materials [37]. These fillers can not only reduce the amount of cement and cementitious materials used but also have significant effects on the strength, durability, and dimensional stability of concrete [8]. In 2018, Khodabakhshian et al. found that the strength and durability of concrete containing marble waste powder tended to decline for replacement ratios over 10%, but satisfactory results were obtained below that level of replacement [9]. In 2018, Davraz et al. investigated the pozzolanic activities and efficiency factors of andesite waste powder and found that the optimum replacement rate of andesite waste powder was 10% for the C40 strength class [10]. In 2010, Aruntaş et al. found that 10% of waste marble dust can be used as an additive material in cement manufacturing [11]. In addition, pumice [12], fly ash [1315], blast furnace [16], and silica fume [17] have also produced good effects in concrete engineering. Most research has focused on the optimal mixing amounts of these fillers, but there is little research on the mechanical properties of concrete with high content of the stone powder.

In recent years, fires have frequently occurred all over the world, causing immeasurable losses. Concrete materials are an important part of global structure, and their fire resistance directly affects the safety of buildings and tunnels. When a concrete structure is exposed to fire, it is very prone to bursting, causing the concrete surface to peel off, thereby destroying the integrity of the components and deteriorating the material properties of the concrete. Because high temperatures have adverse effects on the mechanical and durability properties of concrete structures, it is important to find some solutions to improve the properties of concrete at high temperatures [18]. Some tests show that high temperatures can damage the durability of the properties of concrete; however, the addition of fibers, such as glass fiber [18], polymer fiber [19, 20], steel fiber [21, 22], basalt fiber [23], and hybrid fiber [24], has been shown to compensate for this damage. Basalt fiber is an environmentally friendly and nonhazardous bio-based material that has high tensile strength and high temperature resistance, so it has been widely used in various construction projects [25]. In 2021, Haido et al. found that the splitting tensile strength of self-compacting concrete was increased by adding 0.25% of basalt fiber [26]. In 2020, Mohammadyan-Yasouj et al. found that basalt fiber and alginate were effective at stopping the strength reduction in cement concrete under raised temperatures [27]. In 2020, Wang et al. found that basalt fiber is beneficial to the improvement of the compressive strength of recycled concrete and that basalt fiber has a more significant effect on splitting tensile strength at elevated temperatures. The relative residual splitting tensile strength increases as the basalt fiber content increases [28]. In 2020, Zhou et al. found that the deterioration percentages of both peel and shear interface fracture toughness of basalt FRP-bonded concrete were smaller than those of aramid FRP-bonded concrete [29]. In 2016, Ren et al. found that basalt fiber was effective in improving the strength performance, deformation capacity, and energy absorption property of concrete under high temperatures [30]. This study shows that basalt fiber can improve the performance of concrete under elevated temperatures [31]. In 2020, Haido et al. proposed new models for constitutive relationships to predict the performance of BFRC under tensile and compressive stresses and to estimate its modulus of rigidity after cracking [32]. However, few studies have reported on the mechanical properties of basalt fiber-reinforced concrete with high content of stone powder at high temperatures.

This study, then, aims at investigating the mechanical properties of basalt fiber-reinforced concrete with high content of stone powder at different temperatures (200°C, 400°C, and 600°C) using the high-temperature test, compressive strength test, and nonlinear ultrasonic test of the cube. The influences of the fiber content, fiber length, and temperature on the mechanical properties, inflicting factors, and ultrasonic characteristics of concrete with high content of stone powder are discussed. The research path diagram is shown in Figure 1.

2. Materials and Specimen Preparation

2.1. Stone Powder

Stone powder produced by Jiangxi Xintao Technology Co., Ltd. (Pingxiang, China) was used in the test. The XRD test was carried out using an X-ray diffractometer (Panalytical B.V., the Netherlands) to measure the main mineral compositions of stone powder. The XRD test results are shown in Figure 2. The main mineral compositions of the stone powder used in the test were quartz, albite, K-feldspar, dolomite, clinoptilolite, and biotite. The compositions and contents of the main oxides are shown in Table 1.

2.2. Basalt Fiber

The short-cut basalt fiber was provided by the Haining Anjie Composite Materials Company (Haining, China). The mechanical and physical properties of the basalt fiber were supplied by the manufacturer and are shown in Table 2.

2.3. Cement

Portland cement produced by Changchun Yatai Co., Ltd. (Changchun, China) was used in this study. The strength grade of the cement was M32.5. Its mechanical properties are shown in Table 3, while the chemical composition of the cement is shown in Figure 3.

2.4. Aggregate

Gravel was used as the coarse aggregate, and its particle size was 5–45 mm. Medium-sized river sand was used as the fine aggregate, and its fineness modulus and average particle size were 2.32 and 0.15–1.18 mm, respectively, as shown in Figure 4.

2.5. Concrete Specimen Preparation

The mix ratio selection was designed according to Specification for Mix Proportion Design of Ordinary Concrete in China (JGJ 55-2011). The sand ratio was 33%, and the mixing ratio of the specimens was cement : gravel : stone : water = 1 : 1.49 : 3.02 : 0.50. The lengths of basalt fiber were 6 mm, 12 mm, and 18 mm, and the fiber contents were 1 kg/m3, 3 kg/m3, and 5 kg/m3, respectively. Cube specimens with the size of 150 mm × 150 mm × 150 mm were used in the test to analyze the effect of the stone powder content, in which cement was replaced by stone powder with mass ratios of 15%, 18%, and 21%, respectively. Cube specimens with the size of 100 mm × 100 mm × 100 mm were used for the high-temperature test and mechanical property test, in which cement was replaced by stone powder with a mass ratio of 18%. The specimen preparation process is shown in Figure 5, and the specific steps were as follows.Step 1:In order to mix them completely, cement, sand, stone, stone powder, and fiber were put into a push-type 280 L mixer for dry mixing for 5 min. After the dry powder sufficiently settled, water was added, and the mixture was mixed for another 5 min.Step 2:The mixture was placed into cubical plastic molds, and layered vibration was carried out.Step 3:The molds were placed on a vibrostand with a vibration frequency of 2,850 r/min and shaken for five minutes. Excess mortar on the surface was removed and leveled.Step 4:The plastic molds were placed under an ambient temperature for 12 h, and then after the specimens had attained a certain strength, they were sprayed with water and covered with a plastic film for 3 days.Step 5:The plastic molds were then removed, and the specimens were cured at an ambient temperature for 28 d and then stored in a water tank at an ambient temperature for 102 d.

3. Experimental Procedure and Methodology

3.1. Laboratory Tests
3.1.1. High-Temperature Test

In order to prevent the specimens from bursting due to excessive moisture inside the sample, the cured specimens were placed in a dry box at 80°C for 4 hours and then weighed. The specimens were put into an oven for high-temperature conditioning, i.e., at 25°C, 200°C, 400°C, and 600°C. The temperature-time curves for high-temperature conditioning are shown in Figure 6. The heating rate was 10°C/min. After the specimens reached the target temperatures, they were kept at a constant temperature for 2 hours, and then, they were naturally cooled to room temperature. All the specimens were weighed and tested at an age of 102 days and tested after they were cooled at a laboratory temperature of 18 ± 22°C.

3.1.2. Unconfined Compressive Strength Test

The unconfined compressive strength of the specimens was tested in a computer-controlled electrohydraulic servo universal testing machine according to “standard for test method of mechanical properties on ordinary concrete (GB/T 50081-2002).” Uniform displacement control was used in the test at a loading rate of 0.1 mm/s.

3.1.3. Nonlinear Ultrasonic Test

The nonlinear ultrasonic test is a nondestructive testing method that can be used to measure concrete damage after exposure to high temperatures. The nonlinear ultrasonic testing system consists of a signal generator, a signal amplifier, an oscilloscope, a transmitting transducer, a receiving transducer, and a computer. The test system is shown in Figure 7, and the equipment parameters are shown in Table 4. The working principle of this system is that the electrical signal is emitted by the signal generator, which is amplified in the signal amplifier. Then, the acoustic signal is converted by the transmitting transducer and is transmitted to the concrete specimen. The acoustic signal is received by the receiving transducer and converted into an electrical signal. Finally, the signal is fed back to the oscilloscope.

3.2. Methodology
3.2.1. Response Surface Methodology

In regard to the investigation of the effects of influencing factors on the strength of concrete, several factors, such as the fiber length, fiber content, and temperature, could significantly influence the compressive strength of concrete. However, if just a single variable of the aforementioned factors is analyzed, the cross-impact of the variables is usually neglected. Response surface methodology (RSM) involves using a reasonable experimental design method and obtaining certain data through experiments. A multivariate quadratic regression equation is used to fit the functional relationship between factors and response values. The RSM is a statistical method used to find the optimal process parameters, solve multivariable problems, and perform multifactor interactive analysis through regression equations. The Box-Behnken experimental design (BBD) is one of the common methods used for response surface methodology. It can evaluate the nonlinear relationship between indexes and factors.

3.2.2. Analysis Method of Acoustic Signals Based on S Transform

In this study, the Box-Behnken experimental design was used to conduct an interaction analysis of the influencing factors. The unconfined compressive strength after the exposure to high temperature was used as the output variable. Basalt fiber length X1 (unit: mm), basalt fiber content X2 (unit: kg/m3), and temperature X3 (unit: °C) were used as input variables. The three-factor response test design was carried out. The code and level values of the test factors are shown in Table 5.

3.2.3. Test Scheme Based on BBD Method

The optimized BBD method for this experiment was determined by using Design-Expert design software, with a total of 17 groups and test sites employed. There were 12 factorial points and 5 central points, and the average unconfined compressive strength values of the three specimens were used as the response value for each group. The test scheme based on the BBD method is shown in Table 6.

3.3. Analysis Method of Acoustic Signals Based on S Transform

The analysis method of acoustic signals based on S transform is one of the nonlinear ultrasonic processing methods. The Fourier transform of the entire time series contains information about the spectral components, but it cannot detect time distributions of different frequencies, so for a large class of practical applications the Fourier transform is unsuitable until the time-frequency analysis is proposed and applied in data processing for many research fields. In order to better observe the instantaneous properties of a signal in the time-frequency domain, the S transform was proposed by Stockwell and his coworkers in 1996. The S transform combines the advantages of wavelet transform and short-time Fourier transform and avoids their shortcomings, and the size of the Gaussian window scale in the S transform depends on the reciprocal of the frequency and has the advantages of the multiresolution of the wavelet transform. Furthermore, there is a phase factor in the S transform, which preserves the absolute phase characteristic of each frequency; this is a characteristic that the wavelet transform does not have. Meanwhile, the same as the Fourier transform, the S transform has lossless and reversible characteristics. The one-dimensional continuous S transform is defined aswhere represents the S transform of , denotes the frequency, denotes the time, and controls the position of the Gaussian window on the time axis, which is equivalent to the shift factor in the wavelet transform.

4. Results and Discussion

4.1. Unconfined Compressive Strength Test Results
4.1.1. Influence of Stone Powder Content

The unconfined compressive strength test results of samples with different stone powder content are shown in Figure 8. It can be seen that the unconfined compressive strength of concrete was greatly affected by the addition of stone powder. In the unconfined compressive strength test, it was observed that the unconfined compressive strength of the concrete sample slowly increased with increases in the stone powder content and then significantly decreased. Compared with the specimen without stone powder, the strength of the specimen with 18% stone powder increased by 0.51 MPa, and the strength of the sample with 21% stone powder decreased by 0.97 MPa. The reason for this improvement in the unconfined compressive strength of the concrete specimen is that stone powder plays a certain filling role and improves the compactness of concrete to a certain extent, and the decrease in the unconfined compressive strength of the concrete sample can be attributed to the fact that too much cement was replaced by stone powder, resulting in a decrease in the cementitious material. By curve fitting the intensity and content, the optimal content at the maximum intensity, 18%, was obtained.

4.1.2. Influence of Fiber Content

In order to study the effect of a single factor on the properties of the sample under high-temperature conditions, a temperature of 600°C was selected for analysis. Figure 9 illustrates the relationship between the fiber content and unconfined compressive strength at 600°C. The results show that the strength of the specimens with fiber was higher than that of the specimens without fiber, which indicates that the addition of fiber can effectively improve the strength of specimens and their ability to resist high-temperature damage. The compressive strength of specimens with a fiber length of 12 mm showed an increasing trend before the fiber content reached 1 kg/m3, after which the compressive strength dropped, and finally to the same level as the others. A similar performance was observed in the specimens with a fiber length of 18 mm. The compressive strength of specimens with a fiber length of 6 mm increased with the increase in fiber content from 0 to 3 kg/m3; however, as the fiber content increased further, the compressive strength declined. Hence, the most effective fiber content values for the compressive strength of concrete with high content of stone powder at high temperatures were determined to be 1 kg/m3 (12 mm and 18 mm) and 3 kg/m3 (6 mm). When the fiber content reached 5 kg/m3, the strength of all the specimens with different lengths decreased and tended to be the same, which indicates that good effects cannot be achieved if the fiber content is too large.

4.1.3. Influence of Fiber Length

The relationship between the fiber length and unconfined compressive strength is given in Figure 10. As seen in this figure, the unconfined compressive strength at 600°C of the specimens with fibers of any length was higher than that of the specimens without fiber. However, as the fiber length increased, the unconfined compressive strength first increased and then decreased. The unconfined compressive strength of the specimens with a fiber length of 12 mm and content of 1 kg/m3 was 20% higher than that of the specimens without fiber. The unconfined compressive strength of the specimens with a fiber length of 6 mm and content of 3 kg/m3 was 19% higher than that of specimens without fiber. When the fiber length of 18 mm was added, the unconfined compressive strength of the specimen declined, which indicates that fiber lengths of this size and above do not improve the strength of concrete.

4.1.4. Influence of Temperature

Figure 11 shows the relationship between unconfined compressive strength and temperature. As can be seen, from 25°C to 200°C, the strength value changed little because of the small temperature difference. The compressive strength of specimens with a fiber length of 18 mm and fiber content of 1 kg/m3 showed an increasing trend before the temperature reached 400°C, after which the compressive strength dropped. A similar performance could be observed in the specimens without fiber. The strength of specimens with and without fiber was increased by 30% and 19% at 400°C, respectively. The reason for this is that part of the free water and capillary water existing inside concrete evaporates under a high-temperature environment, which forms a high-temperature steam curing environment to promote the further hydration reaction of cement, so that the strength is improved. From 400°C to 600°C, the strength of specimens with and without fiber was reduced by 33% and 42%, respectively. The reason for this is that the free water and capillary water are lost with increases in temperature, and microcracks and pores form inside the specimens. At the same time, the thermal expansion coefficients of the constitutive materials of the concrete are different, which leads to cracks due to the inconsistency of the thermal deformation. In addition, the crystal structure inside the material is destroyed and decomposed under the action of high temperatures. Therefore, when the temperature reached 600°C, the strength of the specimens began to decline. As can be seen in this figure, the strength of the specimens with fiber decreased even more at 600°C.

4.2. Interaction Analysis of Influence Factors by BBD Method
4.2.1. RSM Model Establishment

Test results based on the BBD method are shown in Table 7. A model fit summary is an evaluation method used to suggest the most suitable model in Design-Expert design software. The variance analysis of the regression model is shown in Table 8. As shown, the sequential p-value of the quadratic polynomial model was less than 0.0001, and the F value representing the significant difference level of the whole fitting model was 51.90, which indicates a good fitting degree. Therefore, it is suggested that the quadratic polynomial fits the unconfined compressive strength response model.

Based on the above analysis and experimental data, the equation of the unconfined compressive strength response value iswhere US represents unconfined compressive strength, MPa; FL represents fiber length, mm; FC represents fiber content, %; T represents temperature, °C.

4.2.2. RSM Model Validation

In order to discuss the effectiveness of the quadratic polynomial regression model, the credibility of the model was analyzed, and the results are shown in Table 9. The model fitting can be analyzed by the determination coefficient R2. The closer R2 is to 1, the higher the model fitting degree is. The determination coefficient R2 of this model was 0.9594, which indicates that the unconfined compressive strength response model had a good fitting. There was a good correlation between the predicted value and the measured value, and the error was small. The correction coefficient of this model was 0.9072, indicating that 90.72% of the response value could be effectively predicted. Therefore, the design model based on the BBD method is effective.

In order to analyze the interaction of various factors, variance analysis and a significance test were performed on the quadratic polynomial model. The statistical parameters in the regression equation are shown in Table 9. The Model F-value of 18.38 implies that the model was significant. There was only a 0.04% chance that a “Model F-value” this large could have occurred due to noise. Values of “Prob > F” less than 0.0500 indicate that model terms are significant. In this case, C2 was significant model term. The F value of each factor reflected its influence effect. The larger the F value, the greater the influence on the response value. It can be seen from Table 10 that the quadratic term (T2) and fiber content (FC) had a significant influence on the response value, and the interaction between the fiber length and the fiber content (FL and FC) was significant.

Figure 12 shows the normal plot of residuals, and Figure 13 shows the relationship between the predicted and actual response values. It can be seen from Figure 12 that almost all points in the residual plot were on a straight line, which indicates that there was a normal error distribution in the test and no abnormal pattern and structure. In the graph of the relationship between the predicted and actual response values, if the point is above the diagonal, it indicates that the actual value was less than the predicted value; if the point is below the diagonal, it indicates that the actual value was greater than the predicted value; if the point happens to fall on the diagonal, it indicates that the difference between the actual value and the predicted value was relatively small. As can be seen from Figure 13, the points in the figure are on the diagonal or evenly distributed on both sides of the diagonal and close to the diagonal, indicating that the predicted value was close to the measured value and that the model has high reliability.

4.2.3. Response Surface Interaction Analysis

Based on the above analysis, the response surface model and contour map under the interaction of the unconfined compressive strength with the fiber content, fiber length, and temperature were obtained, as shown in Figures 14(a)14(c).

As shown in Figure 14(a), there was an optimal fiber content and fiber length at each temperature, and it was optimized when the fiber content was 1 kg/m3 and the fiber length was 18 mm at 400°C. From Figures 14(b) and 14(c), it can be seen that the unconfined compressive strength of fiber-reinforced concrete increased with the increases in temperature and that it reached its maximum at 400°C, which followed the same pattern as that seen in Figure 11. The interaction between two factors can be reflected by the shape of the contour map. The interaction between the two factors is more significant if the contour line in the contour map is elliptical. The contour line in Figures 14(a)14(c) is elliptical, which indicates that the interaction of the fiber content, fiber length, and temperature was significant for the unconfined compressive strength response index.

4.3. Acoustic Signal Analysis

Figure 15 shows the acoustic response signals, the frequency spectrum, and its time-frequency spectrum obtained using S transform of the concrete without fiber and with high stone powder content added at 25°C, 200°C, 400°C, and 600°C, respectively. As can be observed from Figure 15(a), the acoustic response signal consists of a single-frequency signal with a time length of 0.02 seconds, a maximum amplitude of 0.04, and a sampling rate of 100 kHz. After Fourier transform, it can be seen that the maximum amplitude of the acoustic response signal was 0.87, the dominant frequency was 300 Hz, and the time-frequency characteristics of the signal were correctly reflected in the time-frequency spectrum after S transform. When the temperature rose to 200°C, it can be seen in Figure 15(b) that the waveform of the acoustic response signal in the time domain did not change, but the amplitude of the acoustic response signal decreased to 0.03. Likewise, the amplitude of the corresponding frequency spectrum and the time-frequency spectrum was also reduced. When the temperature rose to 400°C, the amplitude of the time domain acoustic response signal was further reduced. At this time, since the amplitude of the effective signal was small enough, it can be seen in Figure 15(c) that the acoustic response signal was slightly disturbed by the background noise. At the same time, the amplitude of the corresponding frequency spectrum and time-frequency spectrum was also further reduced. When the temperature reached 600°C, the amplitude of the acoustic response signal was further reduced, and the background noise caused serious interference to the signal. It can be seen from its frequency spectrum that after a signal with a dominant frequency of 300 Hz was heated at a high temperature of 600°C, the single-frequency acoustic response signal became a full-band signal, and this change can also be clearly seen from its time-frequency spectrum.

The response signal differences in the measured concrete of fiber-free, high stone powder concrete fiber with a length of 18 mm, 3 kg/m3 high stone powder content, and 6 mm high stone powder concrete were compared, and the content was 5 kg/m3. When the temperature rose to 600°C, the time domain acoustic response signals, the frequency spectrum, and the time-frequency spectrum of the three concrete testing blocks are shown in Figure 16. Comparing the three sets of graphs, it can be seen that although the acoustic response signal was severely disturbed by noise after the concrete was heated to 600°C, the amplitudes of the acoustic response signals of different concrete testing blocks did not change much, remaining at the same level. The acoustic response signal of the high stone powder content concrete with a length of 18 mm and content of 3 kg/m3 had relatively higher amplitude values in the time domain, frequency domain, and time-frequency domain. The ability of the specimens to resist cracking was enhanced by adding fibers; fewer cracks were generated under the same heating conditions, and more energy was retained when the signal passed through the specimens. The specimen with a length of 18 mm and content of 3 kg/m3 had higher unconfined compressive strength, and there were fewer cracks on its surface at 600°C, as shown in Figure 17.

5. Conclusions

This study investigated the mechanical properties and influencing factors of basalt fiber-reinforced concrete with high content of stone powder at high temperatures using the high-temperature test, unconfined compressive strength test, and nonlinear ultrasonic test. The following main conclusions were obtained.(1)The cement in concrete was replaced by a stone powder content of 18%, which can improve the strength of concrete. In the application of concrete, replacing cement with high dosages of stone powder can realize the utilization of waste and has good ecological benefits and rapid popularization value.(2)It was found that basalt fiber can effectively improve the cracking resistance of concrete with a high content of stone powder at high temperatures, which provides a broader space for its application at high temperatures.(3)The unconfined compressive strength of concrete was found to increase first and then decrease with increases in the fiber content, fiber length, and temperature. It was found that the interaction between T2 and fiber content, and the interaction between fiber length and fiber content were significant using interactive analysis of the influencing factors based on the BBD method.(4)It was found that as the temperature gradually increased, the amplitude of the single-frequency acoustic response signal in the time domain, the frequency domain, and the signal-to-noise ratio of the signal significantly decreased. The addition of fiber had a certain delaying effect on the crack propagation of concrete at high temperatures, so that fewer cracks were generated under the same heating conditions, and more energy was retained when the acoustic signal passed through the specimen.

Data Availability

The data used to support the findings of this study are available from the corresponding author upon request.

Conflicts of Interest

The authors declare that there are no conflicts of interest regarding the publication of this paper.

Acknowledgments

The authors gratefully acknowledge the experiment and the assistance of the Key Laboratory for Comprehensive Energy Saving of Cold Regions Architecture of Ministry of Education, Jilin Jianzhu University. The research was supported by the National Natural Science Foundation of China (project no. 52008185).