Research Article
Axial Compression Behavior of Circular Concrete-Filled High-Strength Thin-Walled Steel Tubular Columns with Out-of-Code D/t Ratios
Table 3
Summary of test data of circular CFST columns.
| No. of columns | D (mm) | t (mm) | D/t | fc (MPa) | fy (MPa) | Reference |
| 26 | 76.5∼300 | 1.5∼4.5 | 24∼100 | 9.9∼48.4 | 232∼603 | [8] | 18 | 121∼320 | 5∼12 | 10∼46 | 26.6∼46.6 | 249∼294 | [9] | 6 | 100∼101.8 | 0.5∼5.7 | 18∼192 | 18∼37.4 | 244∼320 | [10] | 10 | 159∼1020 | 5.1∼13.3 | 31∼106 | 15∼46 | 291∼382 | [11] | 15 | 165∼190 | 0.9∼2.8 | 59∼221 | 41∼108 | 186∼363 | [12] | 13 | 125∼133 | 1∼7 | 18∼125 | 106 | 232∼429 | [14] | 36 | 133∼168 | 3.3∼5.4 | 25∼50 | 32.3∼58.8 | 325∼392 | [15] | 26 | 60∼250 | 1.9∼2.0 | 32∼134 | 77.2∼82 | 282∼404 | [17] | 31 | 101∼265 | 1.5∼5.4 | 24∼68 | 18.4∼42.7 | 265∼358 | [46] | 13 | 101∼319 | 3.0∼10.4 | 31∼34 | 23.2∼52.2 | 335∼452 | [47] |
|
|