Research Article

Energy Analysis Method for Uniaxial Compression Test of Sandstone under Static and Quasi-Dynamic Loading Rates

Table 3

Linear energy storage fitting formula under the static-quasi-dynamic loading rate.

Loading rates (mm/s)abFitting formula

1.0 × 10−30.410190.20536Ue = 0.41019U + 0.20536
5.0 × 10−30.439120.12641Ue = 0.43912U + 0.12641
1.0 × 10−20.407200.46631Ue = 0.40720U + 0.46631
5.0 × 10−20.431430.3333Ue = 0.43143U + 0.33330
1.0 × 10−10.451950.24409Ue = 0.45195U + 0.24409