Research Article
Finite Element Modeling of Stress Behavior of FGM Nanoplates
Table 1
Nondimensional displacement
of square FGM plates (
a/
hā=ā10) subjected to uniformly distributed load and sinusoidal distributed load.
| Source | N | | 0 | 1 | 2 | 4 | |
| Uniform load | [31] | 0.4666 | 0.9290 | 1.1952 | 1.3908 | 0.4666 | [30] | 0.4665 | 0.9287 | 1.1940 | 1.3890 | 0.4665 | This work | 200 elements | 0.4666 | 0.9376 | 1.1995 | 1.3869 | 0.4666 | 512 elements | 0.4666 | 0.9376 | 1.1995 | 1.3869 | 0.4666 | 800 elements | 0.4666 | 0.9376 | 1.1995 | 1.3870 | 0.4666 | 1800 elements | 0.4666 | 0.9376 | 1.1995 | 1.3870 | 0.4666 |
| Bisinusoidal load | [31] | 0.2961 | 0.5891 | 0.7582 | 0.8831 | 0.2961 | [30] | 0.2960 | 0.5889 | 0.7573 | 0.8819 | 0.2960 | This work | 200 elements | 0.2960 | 0.5945 | 0.7606 | 0.8799 | 0.2960 | 512 elements | 0.2960 | 0.5945 | 0.7606 | 0.8800 | 0.2960 | 800 elements | 0.2960 | 0.5945 | 0.7606 | 0.8800 | 0.2960 | 1800 elements | 0.2960 | 0.5945 | 0.7606 | 0.8800 | 0.2960 |
|
|