Deicing area at different dosing levels.

ParameterTest specimen
PC0.6CFC10.6CFC20.6CFC3

ShapeSpindleSpindleSpindleSpindle
Sc/cm2125.59137.82149.21163.73
a/cm15.3818.7116.8018.22
b1(b)/cm9.1911.4910.6711.28
b2/cm8.496.727.557.45
b3/cm9.1510.8110.9211.00