Research Article

Repeated Uniaxial Compression Test of Permeable Friction Courses Mixtures under Seepage Field and Stress Field Coupling

Table 8

Repeated uniaxial compression test results with non-seepage field.

Repeated uniaxial compression cycles (10000)Total air voids (%)Effective air voids (%)Damage factorPermeability coefficient (m/s)

45023.020.10.0272512.243
29019.815.10.00855113.884
17019.315.00.0069311.883
9019.215.30.005355.525
5019.115.60.003679.418
3019.214.10.0035617.828
2018.814.40.0035525.648
1019.414.850.00355ā€”
019.614.6028.339