Research Article
Design and Experimental Study on Divergent Magnetic Fluid Seal with Large Clearance and Dual Magnetic Sources
Table 1
Structural parameters of divergent magnetic fluid seal with large clearance.
| Parameters | Sizes |
| Inner radius of the first pole shoe (mm) | 14.1 | Inner radius of the second pole shoe (mm) | 17.8 | Inner radius of the third pole shoe (mm) | 21.5 | Outer radius of the first/second/third pole shoe (mm) | 36 | Radius of the first step shaft (mm) | 13.4/13.5/13.6/13.7 | Step height (mm) | 3.7 | Inner radius of the first stage permanent magnet (mm) | 21.5 | Thickness of the first stage permanent magnet (mm) | 6 | Inner radius of the second stage permanent magnet (mm) | 22.5 | Thickness of the second stage permanent magnet (mm) | 4.5 | Outer radius of the first/second stage permanent magnet (mm) | 32.5 | Width of axial sealing clearance (mm) | 0.4/0.5/0.6/0.7 | Height of radial sealing clearance (mm) | 0.4/0.5/0.6/0.7 | Width of pole teeth (mm) | 0.3 | Height of pole teeth (mm) | 0.7 |
|
|