Research Article
Corrosion Investigation of Rock Anchors Served over 10 Years in Underground Powerhouse of a Hydropower Station
Table 9
Exposure ratings of the anchor head structure.
| Position | Quantity (pcs.) | Structure exposure ratings | A | B | C | D |