Research Article

Study on the Mechanical Properties and Design Parameters of Floor Slabs Waste Subgrade Filler

Table 9

Requirements for layered filling thickness and maximum particle size of FSW and detection methods of compaction degree.

Subgrade positionCompacted thickness (mm)Maximum particle size (mm)Detection methods of compaction degree

Upper roadbed150≤50Sand replacement method

Lower roadbed≤300≤100Settlement difference method
Upper embankment≤300≤300
Lower embankment≤400≤300