Research Article

Fracture Analysis of Compressor Impellers in Olefin Units: Numerical and Metallurgical Approach

Table 7

Comparison of simulation results with compressor operating results at rpm 34500 rpm.

Outlet mass flow (kg/hr) HP compressorOutlet mass flow (kg/hr) LP compressor

Simulation result1060011065
Industrial result1149011490
Error7.7%3.6%