Research Article

Experimental Study on Crushing Characteristics of Lignite under Different Load Conditions

Table 2

Relevant parameters of point-load test and calculation results of strength index.

NumberedW (mm)D (mm)P (kN)Is (MPa)F/1Is50 (MPa)

185601.490.251.220.30
296541.860.311.220.38
3104902.060.181.410.25
482751.880.261.270.33
583711.560.221.260.28
6117952.090.161.460.23
796552.040.331.230.40
898501.380.241.210.29
9102823.510.361.360.49
1065550.440.101.130.11
1174520.920.201.140.23
12140551.770.201.330.26
1381620.940.161.220.19
1483651.490.231.240.28
15104551.280.191.250.24
16109571.420.191.280.24
17132652.640.271.360.37
1875601.560.291.190.35
19109521.620.241.250.30
20109652.850.361.300.46
21113561.840.241.280.31
22108662.490.301.310.39
2367501.290.321.110.36
2483551.670.341.160.40
2573551.520.321.150.37
2675702.20.371.220.45
2768551.570.361.130.41

Average value Is50 = 0.32 MPa after removing the minimum and maximum data.