Research Article

Calibration of Contact Parameters for Moist Bulk of Shotcrete Based on EDEM

Table 7

ANOVA of quadratic polynomial model of B-BD test.

Source of variationSum of squaresDfMean squareF valueProbability > F

Model77.76126.48122.070.0002Significant
X1-T22.3112.3143.530.0027
X2-T726.01126.01490.02<0.0001
X3-T310.89110.89205.160.0001
X1 X23.5013.5065.880.0013
X1 X30.2710.275.090.0870
X2 X30.1310.132.440.1932
X1223.44123.44441.62<0.0001
X222.4912.4946.970.0024
X323.7613.7670.760.0011
X12 X26.5216.52122.760.0004
X12X34.3814.3882.530.0008
X1X220.5710.5710.780.0304
Pure error0.2140.053
Cor total77.9716

R2 = 0.9973; R2adj = 0.9891; CV = 0.62%; adequate precision = 41.693.