Research Article

A Novel Two-Disc Machine for High Precision Friction Assessment

Table 2

Measured variables.

Name (abbreviation) Value range

Friction force 0–1000 N
Infrared temperature ()0–160°C
Oil-bath temperature ()0–200°C
Lubrication chamber temperature ()0–200°C
Contact potential ()1–100 mV
LVDT distance ()1 μm–2 mm
Vibration sensor ()0–10 mm/s