Research Article

Determining the Effects of High Intensity Ultrasound on the Reduction of Microbes in Milk and Orange Juice Using Response Surface Methodology

Table 1

The response surface experimental design and results for the log reductions of bacteria and spores in milk and yeast in orange juice.

RunTime (min)Temp. (°C)Amplitude (m)Actual log reduction bacteriaActual log reduction sporesActual log reduction yeastAcoustic power in milk (W)Acoustic power in juice (W)

13412163.371.893.46.195.82
234100.640.01000
31101800.491.00011.1210.59
45101800.451.0504.414.54
51721803.041.345.8510.4010.82
65721804.281.605.852.592.39
7541361.261.200.101.031.00
80.1741360.450.560.2010.227.35
9384367.761.805.900.640.71
1030360.480.1000.681.08
113411080.530.500.403.052.90